Calculators for the building envelope

Pick an element on the house section: the roof, a wall, the window or the floor. Each calculator shows how heat, or sunlight, passes through that element, with climate data for your location.

Section through a house: roof, wall, window and floor, each linking to its calculator 4 Floor 2 Wall 3 Window 1 Roof

Tap the roof, a wall, the window or the floor to open its calculator.

DrawingHouse section
MethodEN ISO · PHPP
Climate dataPVGIS 2005–2023

The four calculators

Four calculators, one for each element: roof, wall, window and floor. They use manufacturer-declared λ values, climate data for the chosen location and the methods of the European standards. Results appear instantly, without an account.

  • U′ and R′ for attic rooms, unheated lofts and flat roofs, including the timber, month-by-month condensation and summer behaviour.

    Worked example

    Attic with 18 cm of wool between the rafters and 5 cm under them: U′ 0.175 W/(m²K). With 10 cm under the rafters: 0.143.

    Open the calculator
  • U′ and R′ for Porotherm or AAC masonry with external insulation, with the temperature through the layers, condensation and a year of heat loss.

    Worked example

    Porotherm 25 N+F with 10 cm of white EPS: U′ 0.304 W/(m²K), i.e. R′ 3.29 m²K/W.

    Open the calculator
  • How much sun reaches the window in each season and how much an overhang shades it, hour by hour, from PVGIS data.

    Worked example

    An unshaded vertical south facade receives on average between 1,018 kWh/m² a year (Brașov) and 1,101 kWh/m² (Craiova).

    Open the calculator
  • A slab on ground for a house without a basement, to EN ISO 13370, with the soil type, plinth insulation and insulation above or below the slab.

    Worked example

    A 120 m² house in Bucharest with 10 cm of polystyrene on the slab loses about 1,422 kWh through the floor in a winter, against 3,644 kWh without it.

    Open the calculator

What the calculators don’t tell you

The calculators describe the physics of a single element in a typical situation. They don’t give ratings or say whether a solution suits your house; that takes a PHPP model of the whole building.

Methods

Standards and data sources

The calculations use public standards and data you can check yourself.

SourceUsed for
Passive House Institute · PHPPPassive House criteria and the energy model of the whole building
Mc 001-2022Romania’s nZEB requirements: the minimum thermal resistance R′ for each element
SR EN ISO 6946Thermal resistance and U-value, including timber and fixings in the element
SR EN ISO 13370Heat transfer through the ground, for the slab on ground
SR EN ISO 13788Condensation inside elements, month by month
SR EN ISO 13786Time lag and damping of the summer heat wave
PVGIS · JRCSolar radiation and temperatures 2005–2023 for each location (European Commission Joint Research Centre)
Declarations of performanceMaterial conductivity λ, taken from manufacturers’ declarations (DoP), not from distributor catalogues